Nutrient + Nutrient Dipslides red spot

TTC Nutrient + TTC Nutrient Dipslides (Box of 10)

The BT2 dipslide (TTC Dipslide) is an all round general purpose Dip Slide that shows total count aerobic bacteria / microbes on both sides of the slide. It is the most popular / widely used dipslide in our range.

£11.96 Tax excluded

By buying this product you can collect up to 11 points

Quantity

Volume discounts

Quantity Price You Save
51 £11.33 Up to £32.14
101 £10.89 Up to £107.75
251 £10.26 Up to £427.48
501 £9.70 Up to £1,131.88
1000 £7.94 Up to £4,024.54

Product specification

Front Agar Type Nutrient TTC
Front Agar Colour Straw
Front Agar Growth Total Count (TTC / Red Spot)
Rear Agar Type Nutrient TTC
Rear Agar Colour Straw
Rear Agar Growth Total Count (TTC / Red Spot)
Shelf Life 6 to 8 months
Certification ISO 9001
Suggested Incubation Times 24 - 48 Hours
Suggested Incubation Temp 30 - 35 °C

Nutrient Agar with TTC; Most Colonies show up as red spots. Ideal for general use in a wide variety of applications and industries. This slide offers a total count on both sides.

It comes in a pack size of 10 slides per box. The slide has a flexible paddle and is located in a shatterproof container. 

Flexible paddle

Flexible Paddle

Each dipslide features a virtually unbreakable and flexible paddle allowing for even, full surface testing.

Easy run off design

Easy Run Off Design

Due to the design of the dipslide, fluids will drain off quickly during testing.

Recessed Handle

Recessed Handle

Each slide has a handle built into the lid that is recessed to help keep your fingers dry during testing.

Side Indicator

Side Indicator

One side of the slide will have a circle indicator so you know which side was used for testing which type of contaminant.

Dual sided paddle

Dual Sided

Each dipslide is dual sided to allow multiple contamination testing with one test.

Thick reliable Agar

Thick Reliable Agar

Each agar is thick (approx 4mm) and raised above the dipslide to allow for easy surface testing.

This agar contains red spot dye which helps the user view and count colonies as they appear as red spots. Nutrient agar will detect / show growth for a wide range of non fastidious organisms. Due to nutrient agar being able to cultivate such a wide variety of micro organisms, it is used in many industries. Applications range from classroom use to water, metalworking fluid and cooling water applications.

How to use the BT2 dipslide

Simply remove the dipslide and immerse in (or pressed against) the sample for approx 10 seconds. Remove dipslide and allow to drain (if necessary) for a few seconds, then replace the slide back into the tube and incubate for a minimum of 24 hours (up to a maximum of 48 hours).

A comparison chart is included so you can easily compare your results.

Remove Nutrient TTC slide from tube

Step 1 : Remove slide

Carefully remove the sterile Nutrient TTC dip slide from its tube ensuring that no contact is made with the agar (to avoid contamination).

Surface testing

Step 2 : If Surface Testing

For surface testing, press the Nutrient TTC dipslide onto the surface. If needed, place a finger on the bottom of the slide (on the plastic, not the agar) to apply extra pressure.

Liquid Testing

Step 2 : If liquid testing

For liquid testing, immerse the Nutrient TTC dipslide into the fluid for 10 seconds then remove and allow to drain for a few seconds.

Swab Testing

Step 2 : If swab testing

Apply a sample of the test substance to a sterile swab and gently apply to the agars.

Incubate the dipslide

Step 3 : Incubate Slide

Label the tube with the included stickers then place the slide into an incubator and allow to incubate.

compare dipslide results

Step 4 : Compare results

Count the amount of colonies that have grown on the slide and compare them to the comparison chart provided.

Industry sectors include

  • General Purpose
  • All water testing and hygiene industries
  • Classroom

Reading the results

Nutrient Side

Level of infection in liquids
(CFU/ml)

102

103

104

105

106

107

Approx colonies per agar

2

12

60

200

500

600+

HSE.gov.uk advice

Good control. Bacteria are being maintained at low levels. No further action is required.

Reasonable control. Review control measures to ensure levels of bacteria remain under control. Risk assessment should specify action to be taken. Biocides and or cleaning may be indicated. If biocides are used, expert advice should be obtained, and the concentration of biocides should be monitored

Poor control. Immediate action should be taken in line with the risk assessment. Normally at very high levels draining and cleaning, should take place.

Example Image

102.jpg 103.jpg 104.jpg 105.jpg 106.jpg 107.jpg

Level of infection on surfaces
(CFU/cm2)

0.4 2.5 12 40 100 250

Customer Questions

Q

Do you have to use incubator for this product? If your your room temp is already 21 degrees C.

A

Yes. The dip slide will need a constant 30 - 35 degrees C temperature for incubation. A room would vary in temperature and in turn can cause inaccurate results.

Q

I want to know expiration date

A

Hello, These items have a minimum shelf life of 6 months.

Q

Do you have a dip slide test kit for machine oils ... ? We have an oil which is used as a coolant, and it is recirculated around a grinding system indefinitely. It is not an emulsion.

A

Hello, We would suggest the metal cutting fluid test kit at https://dip-slides.com/30-kits.

BT2

Download

BT2 Datasheet

BT2 Dipslide Datasheet (PDF)

Download (1.86M)

MSDS

MSDS Sheet for Dipslides

Download (278.29k)

Nutrient Comparison Chart

Nutrient comparison chart in JPG format